Difference between revisions of "Wireless Affective Devices"

From AIRWiki
Jump to: navigation, search
(Dates)
(Dates)
Line 13: Line 13:
 
Start date: 2008/01/08
 
Start date: 2008/01/08
  
Preliminary release by ended on 2008/08/08
+
Preliminary release end: 2008/08/08
  
 
End date: Unknown (WIP)
 
End date: Unknown (WIP)

Revision as of 09:25, 31 October 2008

Part 1: project profile

Project name

Affective Devices

Project short description

The project is aimed at developing affective devices that are able to acquire biological signals such as GSR, BVP, Temperature and Head orientation) in a way that is less invasive for the subject.

Dates

Start date: 2008/01/08

Preliminary release end: 2008/08/08

End date: Unknown (WIP)

Internet site(s)

People involved

Project heads

Other Politecnico di Milano people

Students currently working on the project

Students that have worked on the project

  • Mattia Colombo (Blood Volume Pressure sensor)
  • Alessia Cornaggia (Galvanic skin response sensor)
  • Sala Mirko (Galvanic skin response sensor)

Laboratory work and risk analysis

Laboratory work for this project will be mainly performed at AIRLab/Lambrate. It will include electrical and electronic activity. Potentially risky activities are the following:

  • Use of mechanical tools. Standard safety measures described in Safety norms will be followed.
  • Use of soldering iron. Standard safety measures described in Safety norms will be followed.
  • Use of high-voltage circuits. Special gloves and a current limiter will be used.

Part 2: project description

The project is aimed at developing affective devices that are able to acquire biological signals (such as GSR, BVP, Temperature and Head orientation)in a way that is less invasive for the subject. The term invasive is related to how much the sensors we use compromise the normal interaction.

An affective device should be weared easily, should not have cables and should acquire as much sensors as possible. It is composed by:

  • Blood Volume pressure (Preliminary release by Mattia Colombo)
  • Skin galvanic response (Preliminary release by Sala Mirko e Alessia Cornaggia)
  • Temperature
  • Accelerometer
  • Gyroscope
  • Wireless comunication with a PC
  • Low power, high efficiency, battery power section

Part 2.1: just done in preliminary release

Here is a preliminary release of the headset produced before 2008/08/08 Wd1.jpg

If you are interested on the making of the headset please see making rubber models

* Blood Volume pressure First graph showing a signal acquired with the wireless sensor. Bvp.png

* Skin galvanic response (Sala Mirko e Alessia Cornaggia[1]) Galvanic skin response (GSR), also known as electrodermal response (EDR), psychogalvanic reflex (PGR), or skin conductance response (SCR), is a method of measuring the electrical resistance of the skin. There is a relationship between sympathetic activity and emotional arousal, although one cannot identify the specific emotion being elicited. The GSR is highly sensitive to emotions in some people. Fear, anger, startle response, orienting response and sexual feelings are all among the emotions which may produce similar GSR responses. Response of the skin to the passage of a small electric current. The ease with which the current flows between two points on the skin can be used to indicate stress. When a person is tense or emotional, the sweat glands become more active, increasing moisture on the skin; this allows the electric current to flow more readily. The response may also be used in relaxation training: information about the galvanic skin response is fed back aurally or visually to the subject who can, with practice, learn to increase or decrease sweating on the skin by learning to relax or tense muscles. We measure the galvanic skin response using two electrodes attached to the skin. The optimal placement is the palm of the hands, but we are experimenting other places like on the forehead. The circuit we are creating is the one below.

Circuito.jpg